New website logo 01 01
    Linkedin     
Untitled 1 01

Liberty II

Mattress Replacement

- Digital control panel

- Low air loss system

- Backrest feature 

- Pulsate mode

- Up to a very high risk   

Product code: UPRA367804-2

 

The Liberty II dynamic Low Air Loss mattress replacement provides continuous low pressure and is designed for use with patients considered to be up to a very high risk of developing pressure ulcers. The system is particularly suitable for use with terminally ill and frail patents together with the treatment of burns and lymphoedema.

 

The Liberty II limits both skin warming and moisture accumulation. Constant low pressure provides a gentle support surface that allows patient immersion. Excellent microclimate control helps to reduce the build-up of heat and moisture.

 

The Liberty II enables nursing staff to create a customised care plan for each patient. Pulsate mode intermittently reduces cell pressures by 40% (variable selectable cycles between 1-20 minutes) to help manage oedema and reduce pain by improving blood flow and encouraging lymph flow. Alternating mode with variable cycle times provides pressure redistribution for the prevention and treatment of pressure ulcers.

 

Product information sheet

Liberty II  

 

 

 

 

 

 

 

 

 

 

user manual 01QRG 01

 

 

 

 

 

For further information on this product please contact us on 0845 644 8499 or email us at sales@ultimatehealthcare.co.uk 

 

Features & Benefits


Feature


Benefit


Cell-on-cell construction


Provides excellent pressure reduction and support for patients up to 320kg/ 50 stone


Comfort control


Allows nursing staff to adjust pressures to suit individual patient requirements and provide enhanced comfort and support whilst maintaining a good level of protection and therapy.

True low air loss

Provides a gentle support surface that allows patient immersion.

Pulsate mode

Intermittently reduces cell pressures by 40% (variable selectable cycles between 1-20 minutes) to help manage oedema and reduce pain by improving blood flow and encouraging lymph flow.

Digital control panel

Easy to use digital control panel that offers the intuitive control settings.


Transport mode


Robust and easily activated transport facility allows mattress to remain inflated for up to 24 hours providing a security buffer in case of mains power failure, whilst also facilitating patient/bed movement without unnecessary risk to patient.

Bariatric mode

For use up to 450kg/70 stone.

Lower leg zone

Provides lower residual interface pressure in this highly sensitive area improving patient care.


Rapid CPR deflation


CPR pull and twist release provides rapid deflation for emergency situations to ensure CPR can commence as quick as possible.


Audible and visual alarms


Audible and visual low pressure and power failure alarms enhance patient safety and ensures peace of mind for nursing staff.

Auto-lockout function

Enhances patient safety by preventing accidental or unintentional setting changes. After a period of inactivity the control panel will automatically lockout.


Adjustable hanging brackets


Allows power unit to be securely attached to various beds.


Stretch, waterproof, vapour permeable PU cover


Improves patient comfort and maintains skin integrity by reducing shear and friction forces whilst aiding infection control.

Dynamic cushion

Optional dynamic seat cushion facilities 24 hour care and utilises the Tamora power unit.


Welded seams and enclosed zip


Provides protection against the ingress of fluids into the mattress ensuring maximum protection and longevity for the mattress.


Easily accessible 360° zip


Ensures cover can be easily removed for inspection, infection control and laundry washing.


Integral and covered air pipe


Reduces possibility of fluid ingress to aid infection control.


Securing straps


Provide added stability and ensure the mattress is kept in position on the bedframe.

Cable management system

Eliminates tripping hazardsfrom loose cabling and reduces potential for power damage cable.

 

Technical Specification


Product Code


UPRA367804-2


Risk Category


Up to very high


Max User Weight

320 kg / 50 stone


Warranty


2 years


Mattress Dimensions


2000mm x 890mm x 200mm


Power Unit Dimensions


390mm x 280mm x 185mm


Product Weight


10.5kg Mattress / 6.2 kg Power Unit


Cycle Time (alternating)


5/10/15/20/25/30 Minutes

Cycle time (pulsate)

1-20mins (1 minute intervals)


Pressure range


10-40mmHg


Classification


Class I, Type B


Compliance


Certified to the following standards: EN 60601-1, EN 60601-1-2

 

 

  • Want to check out more?

     

    Go! Call our team now!

    Mon - Fri 8.30am - 5pm

     

     

  • PRESSURE CARE SUPPORT

     

    Go!We have a range of resources that will support your pressure care needs.