Dynamic mattress replacement incorporating continuous turning and turn assist.

 

The Heritage II Digital Turn dynamic mattress replacement system provides very high optimal therapy for the prevention and treatment of pressure ulcers in any care environment. The Heritage II Digital Turn combines a very high risk dynamic mattress with the additional feature of up to 30 degree lateral turn function, reducing interface pressures by up to 50%, resulting in greater stimulation to the capillaries.

 

Manual turning of patients can be intrusive, especially during the night and often results in disturbed sleep. The Heritage II Digital Turn mattress reduces the use of patient care packages.

 

With the option of full, right or left turn up to 30 degrees to assist in a manual or provide automatic turning at variable times between 5 - 30 minutes.

 

The Heritage II Digital Turn is constructed of deep 8” cells, in a cell-on-cell design and provides dual therapy modes i.e. alternating and constant low pressure for patients up to 255kg/40 stone.

 

The static base and head cells provide support and stability, the leg zone provides lower residual interface pressure in this highly sensitive area, while dynamic therapy is provided.

 

The auto-detection  feature allows patient weight/position to be automatically detected and pressure set, ensuring optimum patient comfort.

 

The timed static mode  automatically returns to alternating mode  after 20 minutes, safeguarding patients against the risk of pressure damage.

 

Product code: UPRA3678DT-2

 

Product information sheet

 

her II turn

user manual 01 QRG 01

For further information on this product please contact us on 0845 644 8499 or email us at sales@ultimatehealthcare.co.uk 

 

Features & Benefits


Feature


Benefit


Cell-on-cell construction


Provides excellent pressure reduction and support for patients up to 255kg/ 40 stone


Comfort control


Allows nursing staff to adjust pressures to suit individual patient requirements and provide enhanced comfort and support whilst maintaining a good level of protection and therapy.


Transport mode


Robust and easily activated transport facility allows mattress to remain inflated for up to 24 hours providing a security buffer in case of mains power failure, whilst also facilitating patient/bed movement without unnecessary risk to patient.

Low air loss

Reduces skin heat and moisture by utilising the alternating air after each cycle releasing up to 100 litres of air underneath the cover to ventilate and cool the skin for climate control.

 

True comfort

True Comfort provides a support surface during the alternating cycle which gives a level surface creating further comfort and prevents bottoming out.

  


Rapid CPR deflation


CPR pull and twist release provides rapid deflation for emergency situations to ensure CPR can commence as quick as possible.


Audible and visual alarms


Audible and visual low pressure and power failure alarms enhance patient safety and ensures peace of mind for nursing staff.

Auto-lockout function

Enhances patient safety by preventing accidental or unintentional setting changes. After a period of inactivity the control panel will automatically lockout.


Adjustable hanging brackets


Allows power unit to be securely attached to various beds.


Stretch, waterproof, vapour permeable PU cover


Improves patient comfort and maintains skin integrity by reducing shear and friction forces whilst aiding infection control.


Welded seams and enclosed zip


Provides protection against the ingress of fluids into the mattress ensuring maximum protection and longevity for the mattress.


Easily accessible 360° zip


Ensures cover can be easily removed for inspection, infection control and laundry washing.


Integral and covered air pipe


Reduces possibility of fluid ingress to aid infection control.


Securing straps


Provide added stability and ensure the mattress is kept in position on the bedframe.

Cable management system

Eliminates tripping hazardsfrom loose cabling and reduces potential for power damage cable.

 

Technical Specification


Product Code


UPRA3678DT


Risk Category


Up to very high


Max User Weight

255 kg / 40 stone


Warranty


2 years


Mattress Dimensions


2000mm x 890mm x 200mm


Power Unit Dimensions


360mm x 130mm x 230mm


Product Weight


7.4kg Mattress / 4.6 kg Power Unit


Cycle Time (alternating)


10/15/20/25/30 Minutes


Pressure range


25-60mmHg


Classification


Class II, Type BF


Compliance


Certified to the following standards: EN 60601-1, EN 60601-1-2

 